China - BIMO Machinery has standardized 100 percent copper winding across its three phase asynchronous motor range, together with a revised sealing and bearing assembly on the end shields. The change targets the three complaints buyers raise most often in after sales service: winding burnout, oil and grease leakage, and the cost of frequent maintenance stops.
A motor burns out when the insulation on the winding fails, and insulation fails faster as temperature rises. Copper has a conductivity of about 58 MS per metre, while aluminium is around 35 MS per metre, roughly 60 percent of copper. To carry the same current, an aluminium winding needs a larger cross section and still produces more resistive loss, which means a higher temperature rise inside the slot and at the winding ends.
The practical consequence is well documented in IEC thermal endurance terms: every 10 degrees Celsius of extra temperature rise halves the expected life of Class F insulation. A copper winding that runs 10 to 15 K cooler than an equivalent aluminium winding therefore keeps its insulation healthy for years longer, which is exactly where burnout starts - at the hottest point of the end winding, not at the terminal box.
| Item | Aluminium Winding Motor | Copper Winding Motor |
|---|---|---|
| Conductivity | about 35 MS per metre | about 58 MS per metre |
| Winding temperature rise | 10 to 15 K higher | reference level |
| Typical winding life | 3 to 5 years | 8 to 10 years |
| Rewind or revarnish interval | every 2 to 3 years | every 6 to 10 years |
| Joint and terminal reliability | sensitive to oxidation and creep | stable under thermal cycling |
Leakage on a motor rarely comes from the winding. It usually comes from the bearing chamber, and it is a design and machining issue rather than a wear issue. BIMO addresses it on four points:
| Winding inspection | Insulation resistance check once a year, no rewind expected for 8 to 10 years in normal duty. |
| Bearing service | Grease replenishment at 6,000 to 8,000 running hours for sealed bearing versions, longer with sealed for life bearings. |
| Seal and gasket check | Visual check at each planned shutdown, replacement only when the lip seal shows hardening. |
| Unplanned stops | Copper winding units typically report one day or less per year on fans and pumps, against three to five days for aluminium wound units in the same duty. |
For a plant running dozens of small and medium motors, the difference is not only the rewind cost. It is the production time lost when a fan stops in summer, the labour cost of pulling a motor out of a pump skid, and the risk that a burnt winding damages the driven equipment. Lower maintenance frequency is the outcome buyers actually pay for.
Copper winding is standard on the MS series aluminium housing motors from 0.37 kW to 7.5 kW, on the YE3 and YE4 cast iron series up to 315 kW, and on explosion proof and high voltage ranges. Test reports, winding data and material certificates are supplied with each order, and OEM nameplate and packing are available.
Want to compare the maintenance cost of copper and aluminium winding for your fleet? Send us your motor list and duty cycle, and our engineer will reply with a winding specification and quotation within 12 hours.
Whatsapp:0086-18802094629 Emai:motorexport@bimo-idea.com
China - BIMO Machinery has standardized 100 percent copper winding across its three phase asynchronous motor range, together with a revised sealing and bearing assembly on the end shields. The change targets the three complaints buyers raise most often in after sales service: winding burnout, oil and grease leakage, and the cost of frequent maintenance stops.
A motor burns out when the insulation on the winding fails, and insulation fails faster as temperature rises. Copper has a conductivity of about 58 MS per metre, while aluminium is around 35 MS per metre, roughly 60 percent of copper. To carry the same current, an aluminium winding needs a larger cross section and still produces more resistive loss, which means a higher temperature rise inside the slot and at the winding ends.
The practical consequence is well documented in IEC thermal endurance terms: every 10 degrees Celsius of extra temperature rise halves the expected life of Class F insulation. A copper winding that runs 10 to 15 K cooler than an equivalent aluminium winding therefore keeps its insulation healthy for years longer, which is exactly where burnout starts - at the hottest point of the end winding, not at the terminal box.
| Item | Aluminium Winding Motor | Copper Winding Motor |
|---|---|---|
| Conductivity | about 35 MS per metre | about 58 MS per metre |
| Winding temperature rise | 10 to 15 K higher | reference level |
| Typical winding life | 3 to 5 years | 8 to 10 years |
| Rewind or revarnish interval | every 2 to 3 years | every 6 to 10 years |
| Joint and terminal reliability | sensitive to oxidation and creep | stable under thermal cycling |
Leakage on a motor rarely comes from the winding. It usually comes from the bearing chamber, and it is a design and machining issue rather than a wear issue. BIMO addresses it on four points:
| Winding inspection | Insulation resistance check once a year, no rewind expected for 8 to 10 years in normal duty. |
| Bearing service | Grease replenishment at 6,000 to 8,000 running hours for sealed bearing versions, longer with sealed for life bearings. |
| Seal and gasket check | Visual check at each planned shutdown, replacement only when the lip seal shows hardening. |
| Unplanned stops | Copper winding units typically report one day or less per year on fans and pumps, against three to five days for aluminium wound units in the same duty. |
For a plant running dozens of small and medium motors, the difference is not only the rewind cost. It is the production time lost when a fan stops in summer, the labour cost of pulling a motor out of a pump skid, and the risk that a burnt winding damages the driven equipment. Lower maintenance frequency is the outcome buyers actually pay for.
Copper winding is standard on the MS series aluminium housing motors from 0.37 kW to 7.5 kW, on the YE3 and YE4 cast iron series up to 315 kW, and on explosion proof and high voltage ranges. Test reports, winding data and material certificates are supplied with each order, and OEM nameplate and packing are available.